Ivoclar Te-Econom Flow Light-Cured Flowable Hybrid Composite – 2 g
A light-cured, radiopaque flowable hybrid composite for selected small Class I and II restorations, Class III–V restorations, and deciduous teeth.
Ivoclar Te-Econom Flow is a light-cured, radiopaque flowable hybrid composite developed for selected direct restorative procedures. Its low-viscosity consistency supports controlled placement and adaptation in small or confined preparations where a flowable restorative material is clinically appropriate.
Ivoclar's instructions indicate the material for Class I–V restorations, with Class I and II use limited to small cavities. It is also indicated for selected restorations in deciduous teeth when appropriate isolation, bonding, placement, and light-curing protocols are followed.
Its flowable consistency supports adaptation to internal cavity surfaces and controlled access to narrow preparations. The syringe presentation allows measured dispensing of small quantities. Its radiopacity supports differentiation of the restoration from adjacent tooth structure during postoperative radiographic assessment.
Te-Econom Flow is not self-adhesive. Enamel and dentin must be treated with a compatible adhesive system according to the selected bonding protocol. Adequate isolation is essential because the product should not be used when a sufficiently dry working field cannot be established.
The composite must be placed incrementally. Ivoclar's referenced instructions specify increments of up to 2 mm, with each layer polymerised individually according to the curing-light intensity. The current instructions supplied with the product should take priority if the curing recommendations have changed.
Indications
- Direct restoration of small Class I cavities
- Direct restoration of small Class II cavities
- Direct Class III restorations
- Direct Class IV restorations
- Direct Class V restorations
- Selected restorations in deciduous teeth
- Small or confined preparations where a flowable composite is clinically appropriate
- Light-cured flowable hybrid composite
- Radiopaque formulation
- Suitable for selected direct restorative procedures
- Indicated for small Class I and II cavities
- Suitable for Class III–V restorations
- Suitable for selected restorations in deciduous teeth
- Flowable consistency supports adaptation in small preparations
- Syringe delivery supports controlled dispensing
- Incremental placement with individual light curing
- Designed for use with a compatible adhesive system
- Available in A2 and A3 shades
- Supplied as a 2 g syringe
- Intended for professional dental use
Pack Contents
- 1 × 2 g Te-Econom Flow syringe in the selected shade
Available Shades on This Product Page
| Shade | Presentation |
|---|---|
| A2 | 1 × 2 g Syringe |
| A3 | 1 × 2 g Syringe |
Select the required shade before adding the product to the cart.
| Attribute | Specification |
|---|---|
| Brand | Ivoclar |
| Product Name | Te-Econom Flow |
| Product Type | Flowable Hybrid Composite |
| Restorative Type | Direct Composite Restorative |
| Curing Method | Light Cure |
| Light Wavelength | 400–500 nm |
| Radiopacity | Radiopaque |
| Consistency | Flowable |
| Clinical Application | Selected Anterior and Posterior Restorations |
| Cavity Classes | Small Class I and II; Class III–V |
| Deciduous Teeth | Suitable for Selected Restorations |
| Maximum Increment Thickness | 2 mm |
| Placement Technique | Incremental |
| Available Shades | A2 and A3 |
| Presentation | Syringe |
| Net Quantity | 2 g |
| Intended User | Qualified Dental Professional |
Technical values are based on the referenced Ivoclar instructions. The current IFU and information printed on the supplied product must take priority if any specification has changed.
Composition
Te-Econom Flow contains:
- Dimethacrylates: 37 wt%
- Inorganic fillers: 62 wt% or 38 vol%
- Inorganic filler particle size: 0.04–7 µm
- Initiators
- Stabilisers
- Pigments: 1 wt%
The manufacturer's referenced IFU identifies the material as a dimethacrylate-based flowable composite with inorganic fillers, initiators, stabilisers, and pigments.
Curing Recommendations
| Curing-Light Intensity | Recommended Exposure Time |
|---|---|
| ≥500 mW/cm² | 20 seconds |
| ≥1000 mW/cm² | 10 seconds |
| ≥2000 mW/cm² | 5 seconds in Turbo mode |
These values come from the referenced Ivoclar instructions. Confirm them against the current IFU supplied with the product and the validated output of the curing unit.
- Select the required shade before isolation, while the tooth is still hydrated.
- Establish adequate isolation, preferably with a rubber dam where clinically appropriate.
- Prepare the cavity according to the requirements of the planned adhesive restoration.
- Clean the preparation with water spray.
- Gently dry the preparation without over-desiccating the dentin.
- Provide appropriate pulp or dentin protection in deep preparations where clinically indicated.
- Place a matrix and interdental wedge where required.
- Condition and bond enamel and dentin using a compatible adhesive system, following its instructions.
- Confirm complete adhesive coverage and polymerise the bonding agent as directed by its manufacturer.
- Dispense Te-Econom Flow directly from the syringe using a clean application tip or suitable restorative instrument.
- Apply the material in increments not exceeding 2 mm.
- Adapt the material within the preparation, taking care not to trap air.
- Polymerise each increment separately, in line with your curing light's intensity and the current Ivoclar recommendations.
- Keep the curing-light tip as close as practical and correctly oriented toward the material.
- Finish the restoration with suitable finishing instruments or fine diamonds.
- Check margins, proximal contacts, and occlusion where applicable.
- Polish the restoration with an appropriate composite-polishing system.
- Replace the syringe cap immediately after dispensing.
For professional dental use only.
Clinical Considerations
- Te-Econom Flow is not self-adhesive and requires a compatible adhesive system.
- Use only where a sufficiently dry working field can be established.
- Class I and II indications are limited to small cavities.
- Do not use as an unrestricted replacement for a conventional sculptable posterior composite.
- Apply in increments of no more than 2 mm.
- Polymerise each increment individually.
- Check curing-light output regularly — insufficient irradiance can reduce polymerisation.
- Curing time depends on light intensity, curing distance, tip orientation, and equipment condition.
- Avoid contamination with saliva, blood, or moisture after bonding.
- Direct pulp capping with Te-Econom Flow is contraindicated.
- Protect areas close to the pulp with an appropriate pulp/dentin protective material where clinically indicated.
- Do not use in patients with known hypersensitivity to any listed component.
- Stop using the material if sensitisation occurs.
- Avoid contact of uncured material with skin, mucosa, and eyes.
- Eugenol- or clove-oil-containing materials may inhibit the polymerisation of methacrylate-based materials.
- Cationic mouthwashes, plaque-disclosing agents, and chlorhexidine may contribute to discolouration.
- Use only for manufacturer-supported indications and according to the current instructions supplied with the product.
Contraindications
Do not use:
- When adequate isolation cannot be achieved
- When the specified application technique cannot be followed
- In patients with known allergy to any component
- For direct pulp capping
Safety Information
- Unpolymerised material may irritate skin or oral mucosa.
- Methacrylate components may cause sensitisation in susceptible individuals.
- Avoid unnecessary contact with uncured composite.
- Standard medical gloves do not provide complete protection against methacrylate sensitisation.
- Use appropriate protective measures and minimise direct handling of uncured material.
Storage and Handling
- Store at 2–28°C.
- Protect the syringe from direct light and excessive heat.
- Close the syringe immediately after use.
- Exposure to light may cause premature polymerisation.
- Follow the expiry date printed on the syringe or packaging.
- Do not disinfect the syringe with oxidising disinfectants.
- Keep the dispensing opening clean and free from contamination.
- Do not use material that has expired or developed an abnormal consistency.
| Brand | Ivoclar Vivadent |
|---|
To facilitate accurate invoicing and maintain tax compliance, we kindly request that you provide your GST number.
Why is this necessary?
The GST number enables us to issue precise invoices for your order, ensuring adherence to tax regulations.
Please fill out your Registration Number / ID
To proceed with your order, kindly enter your Medical Registration number or Medical ID.
Change Pincode
Variant Price
| Variant | Price |
|---|---|
| Shade A2 - Shade A3 | ₹735.00 |
Want to buy even more quantity?
Get Bulk Quote Now